Certifications 2
Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau
Item no.: 1601920
Material Safety Data Sheet
6. Accidental Release Measures
Personal precautions, protective equipment and emergency procedures:
As an immediate precautionary measure, isolate spill or leak area for at least 25 meters (75 feet) in all directions. Keep
unauthorized personnel away. Stay upwind. Keep out of low areas. Ventilate closed areas before entering.
Wear adequate personal protective equipment as indicated in Section 8.
Environmental precautions
Absorb spilled material with non-reactive absorbent such as vermiculite, clay or earth. Prevent from migration into soil, sewers
and natural waterways – inform local authorities if this occurs.
Methods and material for containment and cleaning up
Evacuate spill area immediately and remove sources of ignition. Do NOT touch spilled material. Cleanup personnel must be
trained in the safe handling of this product. Spills may be absorbed on non-reactive absorbents such as vermiculite. Place cells
or batteries into individual plastic bags and then place into appropriate containers and close tightly for disposal. Ensure that
cleanup procedures do not expose spilled material to any moisture. Immediately transport closed containers outside. Lined
steel drums are suitable for storage of damaged cells or batteries until proper disposal can be arranged.
7. Handling and Storage
Precaution for Handling
Avoid short circuiting the cell. Avoid mechanical damage of the cell. Do not open or disassemble.
Advice on protection against fire and explosion
Keep away from open flames, hot surfaces and sources of ignition.
Condition for storage
Storage at room temperature (approx. 20°C) at approx. 20~60% of the nominal capacity (OCV approx. 3.6 - 3.9 V/cell). Keep
in closed original container.
8. Exposure controls/personal protection
Exposure Control Measures
Exposure Limit Values:
Airborne exposures to hazardous substances are not expected when the cells or batteries are used for their intended
purposes. Exposure standards are not applicable to the sealed articles.
Biological Monitoring:
Not applicable.
Control Banding:
Not applicable.
Recommended monitoring procedures:
Follow standard monitoring procedures.
Derived no-effect level (DNEL):
Not applicable.
Page 6 of 13