Certifications 2

Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau
Item no.: 1601920
Material Safety Data Sheet
3. Composition/information on ingredients
Hazardous components
Chemical Name CAS No. *Mass range in cell (g/g %)
Electrolyte Contains Electrolyte salt and solvents. / 5 - 20
Electrolyte salt Lithium hexafluorophosphate 21324-40-3 0.05 - 5
Electrolyte solvent Includes one or more of the following;
Ethelyne Carbonate
Propylene Carbonate
Diethyl Carbonate
Ethyl propionate
96-49-1
108-32-7
105-58-8
105-37-3
5 - 20
PVDF Polyvinylidenfluoride 24937-79-9 <1
Copper Cu 7440-50-8 3 - 15
Aluminium Al 7429-90-5 2 - 10
Cathode Lithium cobalt oxide 12190-79-3 20 - 50
Anode Graphite 7782-42-5 10 - 30
Steel, Nickel, and inert
components
Various Balance
Because of the cell structure the dangerous ingredients will not be available if used properly.
During charge process a lithium graphite intercalation phase is formed.
4. First Aid Measures
Description of first aid measures
The hazardous components of this cell or battery are contained within a sealed unit. The following measures are only
applicable if exposure has occurred to components when a cell or battery leaks, is exposed to high temperatures or is
mechanically, electrically or physically abused/damaged. The hazardous contents are caustic alkaline electrolytes contained in
cells with lithium metal oxide cathodes, graphite and carbon anodes and Polyvinylidenfluoride binders.
Ingestion:
Have victim rinse mouth thoroughly with water. DO NOT INDUCE VOMITING. Quickly transport victim to an emergency care
facility.
Eye:
If eye contact with contents of an open cell occurs, immediately flush the contaminated eye(s) with water. Quickly transport
victim to an emergency care facility.
Skin Contact:
Immediately flush with water. If irritation or pain persists, seek medical attention.
Inhalation:
Remove the patient from exposure into fresh air, seek medical attention.
Page 4 of 13