Pre-start checks:
3
Fuel (see page 39)
Check that there is enough fuel in the tank.
Ifnecessary,rellthetank.
4
Engine oil (see page 40)
Check that there is enough engine oil.
Ifnecessary,addthespeciedamountofrecommendedoil.
Check for oil leaks from the generator.
5
If an anomaly is detected during use
Check whether the generator is operating correctly.
Ifnecessary,addthespeciedamountofrecommendedoil.
If necessary, contact a specialist.
10 Operation
(WARNING)
Never operate the engine in a closed room, as this can quickly lead to unconsciousness and death. Operate the
engine in a well-ventilated place.
Do not connect any electrical devices before starting the engine.
(IMPORTANT)
Thegeneratorissuppliedwithoutengineoil.Donotstarttheengineuntilthesufcientamountofengineoilhas
been added.
Donottiltthegeneratorwhenaddingtheengineoil.Thiscouldresultinoverllingandcausedamagetothe
engine.
TIP: The generator can be used with the rated output power under standard atmospheric conditions.
1
“Standard atmospheric conditions”:
Ambienttemperature: 25˚C
Barometric pressure: 100 kPa
Relative humidity: 30 %
The output power of the generator varies depending on the ambient temperature, altitude (lower air pressure at higher
altitudes) and humidity.
The output power of the generator will drop if the temperature, humidity and altitude are higher than the standard
atmospheric conditions.
In addition, the current load must be reduced if the generator is used in a narrow space, as this affects the cooling
of the generator.