Operation Manual

40
14. Volume measurement
1. Push the button FUNC (G) twice. The display shows a cube to
indicate volume measurement mode.
2. Activate the target laser (B) by pushing the button ON (C).
3. Push the button ON to measure the rst side length of the space.
The measurement is shown in the upper line.
4. Activate the target laser by pushing the button ON.
5. Push the button ON to measure the second side length of the space.
The measurement is shown in the middle line.
6. Activate the target laser by pushing the button ON.
7. Push the button ON to measure the height of the space. The
measurement is shown in the middle line.
8. The device multiplies all three readings automatically. The volume of
the space is shown in the bottom line.
15. Indirect measurement
By applying the Pythagorean theorem (a
2
+b
2
=c
2
), the height of an object
can be determined indirectly.
1. Push the button FUNC (G) three times. A triangle is shown at the top
of the display to indicate indirect measurement.