Certifications 2

Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau
Item no. : 886593
Material Safety Data Sheet
10. Stability and reactivity
10.1. Reactivity
No hazardous reaction when handled and stored according to provisions.
10.2. Chemical stability
No decomposition when stored and handled properly
10.3. Possibility of hazardous reactions
Reaction with strong oxidising agents Alkalis (alkalis). Acids
10.4. Conditions to avoid
The product does not contain any relevant quantities of substances with workplace-related limit values to be monitored.
10.5. Incompatible materials
Keep away from oxidising agents.
10.6. Hazardous decomposition products
No decomposition when stored and handled properly. In case of fire may be liberated: toxic and caustic gases and vapours
11. Toxicological information
11.1. Information on toxicological effects
Acute toxicity
CAS No. Chemical name
Exposure route Dose Species Source
25068-38-6 Epoxy resin (number average molecular weight <= 700), reaction product: bisphenol-A-(epichlorhydrin)
oral LD50 11400 mg/kg Rat GESTIS
dermal LD50 > 22800 mg/kg Rabbit GESTIS
16096-31-4 1,6-Bis(2,3-epoxypropoxy)hexane
oral LD50 3010 mg/kg Rat OECD 401
dermal LD50 > 2000 mg/kg Rat OECD 402
28064-14-4 Phenol, polymer with formaldehyde, glycidyl ether
oral LD50 > 2000 mg/kg Rat
dermal LD50 > 2000 mg/kg Rat
Additional information on tests
The mixture is classified as hazardous according to regulation (EC) No 1272/2008 [CLP].
Page 7 of 12