Certifications 2
Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau
Item no.: 886523
Material Safety Data Sheet
8. Exposure controls/personal protection
8.1 Control parameters
Occupational exposure limit values:
CAS No. Designation Type Limit value
- Hydrocarbons, C7, n-alkanes,
isoalkanes, cyclics
Great Britain: WEL-TWA
Great Britain: WEL-TWA
1200 mg/m³
(> or = C7, Normal and
branched chain alkanes)
800 mg/m³
(> or = C7, Cycloalkanes)
64742-49-0 Hydrocarbons, C6-C7, n-
alkanes, isoalkanes, cyclics,
<5% n-hexane
Great Britain: WEL-TWA 1800 mg/m³ (C5-C6 alkenes)
115-10-6 Dimethyl ether Europe: IOELV: TWA
Great Britain: WEL-STEL
Great Britain: WEL-TWA
Ireland: 8 hours
1920 mg/m³; 1000 ppm
958 mg/m³; 500 ppm
766 mg/m³; 400 ppm
1920 mg/m³; 1000 ppm
8.2 Exposure controls
Provide for good ventilation or exhaust system or work with completely self-contained equipment.
Personal protection equipment
Occupational exposure controls
Respiratory protection:
Respiratory protection must be worn whenever the WEL levels have been exceeded.
Use filter type ABEK acc EN 14387.
The filter class must be suitable for the maximum contaminant concentration (gas/vapour/aerosol/particulates) that may arise
when handling the product. If the concentration is exceeded, self-contained breathing apparatus must be used.
Hand protection:
Protective gloves according to EN 374.
Glove material: Nitrile rubber - Layer thickness: >= 0.45 mm
Breakthrough time: >= 240 min
Observe glove manufacturer's instructions concerning penetrability and breakthrough time.
Eye protection:
Tightly sealed goggles according to EN 166.
Body protection:
Wear suitable protective clothing.
Page 7 of 15