8. Troubleshooting
By purchasing this circular saw, you have acquired a product design to the state of the art and operationally reliable.
Nevertheless,problemsorerrorsmayoccur.
The following contains description for the removal of possible interference.
Always observe all safety information in these operating instructions.
Problem Causes Solutions
The electrical tool fails to start
Power supply line disconnected Check the electric power supply line
Plug not inserted Insert the plug in the electric power
supply socket and press the start button
Worn graphite brushes Contactanauthorizedservicecentre
Electrical fault Contactanauthorizedservicecentre
The electrical tool starts but does
not cut well. The electrical tool
vibrates a lot.
Worn, dull or damaged blade Replace the blade
Incorrectly assembled blade Disassemble the blade and reassemble
it correctly
9. Care and cleaning
Always disconnect the device before performing any adjustment or maintenance operation. If the supply
cordisdamaged,itmustbereplacedbythemanufactureroritsserviceagentinordertoavoidahazard.
a) Cleaning
Avoid using solvents when cleaning plastic parts. Most plastic parts are susceptible to damage from
various types of commercial solvents and may be damaged by their use.
• Use clean cloths to remove dirt, carbon dust, etc.
• Disconnect from the power supply immediately if the supply cord is damaged.
• Take care not to expose this tool to the rain.
b) Lubrication
Allthebearingsinthistoolarelubricatedwithasufcientamountofhighgradelubricantforthelifeoftheunitunder