Certifications 2

Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau
Item no.: 886558
Material Safety Data Sheet
8. Exposure controls/personal protection
8.1. Control parameters
Exposure limits (EH40)
CAS No. Substance ppm mg/m³ fibres / ml Category. Origin
123-86-4 n-butyl acetate 150
200
724
966
TWA (8 h)
STEL (15 min)
WEL
WEL
8.2. Exposure controls
Appropriate engineering controls
Provide adequate ventilation as well as local exhaustion at critical locations. In case of inadequate ventilation wear respiratory
protection.
Protective and hygiene measures
After contact with skin, wash immediately with plenty of water and soap.
Eye/face protection
Tightly sealed safety glasses.
Hand protection
Wear suitable gloves. (DIN EN 374)
Thickness of glove material: > 0,4 mm
penetration time (maximum wearing period): > 480 min
When handling with chemical substances, protective gloves must be worn with the CE-label including the four control digits.
The quality of the protective gloves resistant to chemicals must be chosen as a function of the specific working place
concentration and quantity of hazardous substances. For special purposes, it is recommended to check the resistance to
chemicals of the protective gloves mentioned above together with the supplier of these gloves.
Protect skin by using skin protective cream. Use protective skin cream before handling the product.
Skin protection
Wear suitable protective clothing. (antistatic) Natural fibres (e.g. cotton), heat-resistant synthetic fibres.
Respiratory protection
In case of inadequate ventilation wear respiratory protection. Observe the wear time limits according GefStoffV
in combination with the rules for using respiratory protection apparatus (BGR 190). Use only respiratory protection equipment
with CE-symbol including four digit test number.
Environmental exposure controls
Do not allow to enter into surface water or drains. See chapter 7. No additional measures necessary.
Page 6 of 13