13.7 Spider Box Removal
13.7.1 Once it is determined that an adjustment is required, remove the spider assembly
from the gearbox sha as follows:
13.7.2 Remove the zerk fitting and allen head screw designated by the letter “S.
13.7.3 On the opposite side of the spider block, there is another zerk fitting and allen head
screw. Remove both of these components.
13.7.4 Li the upper trowel assembly off of the spider assembly.
NOTE
A slight tap with a rubber mallet may be necessary to dislodge the spider from the main sha of the gearbox.