Use and Care Manual
19
SYMPTOM
POSSIBLE CAUSES
SOLUTION
Not enough power
available (compression
normal, no misfiring)
Ignition coil defective?
Ignition plug oen shorts?
Flush fuel system and replace fuel.
Replace ignition wires, clean ignition.
Fuel is inadequate (water, dust)? Flush fuel system and replace fuel.
Engine overheats.
Mixed fuel quality is inadequate?
Excessive carbon deposition in
combustion chamber?
Check fuel to oil mixture.
Clean or replace crankcase.
Exhaust or muler clogged with
carbon?
Clean or replace muler.
Spark plug heat value incorrect? Replace spark plug with correct type
spark plug.
Rotational speed
fluctuates.
Governor adjustment improper?
Governor spring defective?
Adjust governor to correct lever.
Clean or replace ignition.
Fuel flow restricted?
Check entire fuel system for leaks or clogs.
Air taken in through suction line?
Check suction line.
Recoil starter
malfunction.
Debris in recoil starter track?
Spiral spring loose?
Clean recoil starter assembly.
Replace spiral spring.
4. TECHNICAL DATA
Model
Engine type
Engine speed operating RPM
Power (hp)
Weight (lb)
Impact force (kN)
Jumping stroke (in)
Fuel tank capacity (L)
Shoe size (in)
Ramming system lubrication
JUMPING JACK
Honda GX100
3800±100
3.0
132
10.7
2 - 3.4
0.
6 gal
13 x 10
0.8 L, CD10W-30