SYMPTOM POSSIBLE CAUSE SOLUTION
Ignion coil defecve Flush fuel system and replace fuel
Ignion plug shorts
Replace ignion wires, clean
ignion
Fuel is inadequate (water, dust) Flush fuel system and replace fuel
Mixed fuel quality is inadequate Check fuel to oil mixture
Excessive carbon deposion in
combuson chamber
Clean or replace crankcase
Exhaust or muer clogged with
carbon
Clean or replace muer
Spark plug heat value incorrect
R
eplace spark plug with correct
type spark plug
Governor adjustment improper Adjust governor to correct lever
Governor spring defecve Clean or replace ignion
Fuel ow restricted
Check enre fuel system for leaks
or clogs
Air taken in through sucon line Check sucon line
Debris in recoil starter track Clean recoil starter assembly
Spiral spring loose Replace spiral spring
Not enough power available
(Co
mpression normal, no misring)
Engine overheats
Rotaonal speed uctuates
Recoil starter malfuncon