Installation Manual

Installation Steps of LZ bracket for In-swinging doors
g
n
i
g
n
i
w
-
s
I
n
300 lbs serial
600 lbs serial
800 lbs serial
1200 lbs serial
-------
48mm
54mm
76mm
Model "X" value
The "X" value in the table below for each
bracket to mount on the door frame,
shows the minimum requirement width of
the door frame for different electromagnetic
lock model.
X
In-swinging
X
2
Tighten the electromagnetic lock
on the L bracket by using the
fixing screw.
1
Find a mounting location on the
door frame for the L bracket. Make
sure that the door is still closeable.
6
Close the door. Measure the correct
position by bringing the armature
plate close to the contact surface of
the electromagnetic lock.
Power
7
Turn on the power of EM-Lock,
and let the armature plate bonds
to the EM-lock. Adjust the position
between the Z bracket and the
door frame.
Finish
Once the position is correct,
use the screws to permanently
mount the Z bracket on the door
frame. This should be the last step.
4
Insert the guide pins into the
armature plate. The guide pins
will prevent the armature plate to
pivot around.
5
Put one rubber washer between
armature plate and the Z bracket,
and place them over the 8mm
armature screw.
3
Assemble the Z bracket, and make
sure that the Z bracket is adjustable.
With LZ bracket for In-swinging doors
Connecting Diagram
++
++
--
--
N.O.
COM.
N.C.
Power
Input
Power
supply
Trigger
SPDT relay
3A@12VDC
Status LED:
GREEN: Unlocked
RED : Locked
Off: No power
Coil
Sensor input
Timer Adjust
Shorten
4-3
12Vdc
24Vdc
Voltage Selection jumpers
Check jumper settings before
connecting the lock to 24 VDC
input power. Damage to the
lock may result from incorrect
jumper settings.
N.C. output while door is unlocked ;
N.O. Output while door is locked by
the electromagnetic lock.
Magnet bond
sensor output
Control Device N.C. contact or
Access Relay
Door Held Open Alarm
"Door Held Open Alarm"
Door Held Open
Alarm
If the "Door Held Open Alarm" timer is set for 5 seconds, the following
will happen: If the door has been opened , but has remained open for
more than 5 seconds then an audible alarm will sound until the door
has been closed correctly.
The time for the is depending on the "VR
timer adjust"within 90 seconds. The models with "
" functionare:10002BZ,10005BZ,10020BZ, 10040BZ.
The electromagnetic lock will automatic unlock internally after the
triggers connect to each other. The time for the door to relock back is
depending on the "VR timer adjust" within90 seconds. The models
w i t h " t r i g g e r " f u n c t i o n a r e : 1 0 0 0 1 T D , 1 0 0 0 2 T D , 1 0 0 0 4 T D ,
10005TD,10010TD10020TD,10060TD,10040TD
N.C. output while door is opened ; N.O. output while door is closed to
the electromagnetic lock.
T h e m o d e l s w i t h " D o o r P o s i t i o n S e n s o r " f u n c t i o n a r e :
1 0 0 0 2 D S , 1 0 0 2 0 D S , 1 0 0 0 4 D S , 1 0 0 4 0 D S , Re e d s w i t c h ra t e d
0.25A@30VDC
Relocking timer
Door Position Sensor
N.O.
Com.
N.C.
Orange:
White:
Brown:
Copyright Gianni Industries, Inc. All Rights Reserved.