User's Manual

6
5. AC Line Voltage
5-1 The amplifier is designed to work with AC 240 V (200- 250 V).
5-2 The correct AC plug (not included in the package), must be obtained
locally due to the AC plug variations worldwide.
5-3 The AC voltage has been factory preset for 240 V use (or as requested
by the customer at the time of order). See the other illustration for AC voltages
other than 240 V. For your safety, before making these adjustments, be sure to
pull the AC plug from the AC outlet to avoid injury.
AC Line Tap 1 Tap 2
200V (195V-205V) 0 V 200 V
210V (205V-215V) 10 V 220 V
220V (215V-225V) 0 V 220 V
230V (225V-235V) 10 V 240 V
240V (235V-245V) 0 V 240 V
250V (245V-255V) 0 V 250 V
Guide for Tap Selection
T1 (Main Power Transformer)
250V
240V
220V
200V
10V
AC-N
Tap 1
0V
AC-L Tap 2
10V
Secondary
Winding
250V
240V
240V
240V
240V
240V
240V
220V
220V
220V
220V
220V
220V
200V
200V
200V
200V
200V
200V
10V
10V
10V
10V
10V
10V
0V
Terminal Board Connection
AC200V
AC210V
AC220V
AC230V
AC240V
AC250V