User guide
  - 21 - 
5.1  List of settings in the pattern No. setting and program setting modes 
Name 
Setting content 
Initial value 
1 
SV * 
Setting temperature (*1) 
- (Termination of a run); SLL to SLH 
0 
2 
W * 
Wait function setting (*1) 
0 to 4 (0 stands for no function) 
0 
3 
TS1 * 
Time signal 1 function setting (*1) 
0 to 5 (0 stands for no function and 5 for in-a-selection step ON) 
0 
4 
TS2 * 
Time signal 2 function setting (*1) 
0 to 5 (0 stands for no function and 5 for in-a-selection step ON) 
0 
5 
TS3 * 
Time signal 3 function setting (*1) 
0 to 5 (0 stands for no function and 5 for in-a-selection step ON) 
0 
6 
TS4 * 
Time signal 4 function setting (*1) 
0 to 5 (0 stands for no function and 5 for in-a-selection step ON) 
0 
7 
ML * 
Operation amount limiter function setting (*1) 
0 to 4 (0 stands for no function) 
0 
8 
T * 
Setting time (*1) 
0:00 to 99:59 (hour: minute); ~ (endless setting) 
00:00 
9 
RNC 
running times 
0 - 99 times (0 for infinite number) 
1 
10 
E ON 
End signal ON time 
0:00 to 99:59 (hour: minute); ~ (ON hold) 
00:00 
5.2  Common  parameter  setting  mode  SET  1 
SET01 
Name 
Setting content 
Initial value 
1 
PAT 
Number-of-patterns setting (*2) (*3) 
1 to 15 (pattern) 
1 
2 
PVSV 
PV start/SV start selection (*2) 
PV 
PV start 
PV 
SV 
SV start 
3 
SVSV 
Start temperature setting at SV start (*2) 
Thermocouple/RTD input SLL to SLH (C) 
0 
Current/voltage input SLL to SLH (digit) 
4 
RNES 
In-a-run output/end signal output selection 
(*2) 
0 
In-a-run output 
0 
1 
End signal output 
5 
ERUN 
External drive signal selection (*2) 
OFF 
Internal run 
OFF 
ON 
External run 
6 
TPV 
Power outage restoration temperature width 
setting 
Thermocouple/RTD input 0.0 to 2999.9 (C) or 0 to 2999 (C) 
0 
Current/voltage input 0 to 29999 (digit) 
5.3  Common  parameter  setting  mode  SET  2 
SET02 
Name 
Setting content 
Initial value 
* Below, 1 and 2 are for the wait function setting, i.e., effective when 1 is selected.   
1 
WZ1 
Wait zone 1 setting 
Thermocouple/RTD input 0.0 to 999.9 (C) or 0 to 999 (C) 
0 
Current/voltage input 0 to 9999 (digit) 
2 
WT1 
Wait time 1 setting 
0:00 to 99:59 (hour: minute) 
00:00 
* Below, 3 and 4 are for the wait function setting, i.e., effective when 2 is selected.    
3 
WZ2 
Wait zone 2 setting 
same as Wait zone 1 
0 
4 
WT2 
Wait time 2 setting 
00:00 
* Below, 5 and 6 are for the wait function setting, i.e., effective when 3 is selected.    
5 
WZ3 
Wait zone 3 setting 
same as Wait zone 1 
0 
6 
WZ3 
Wait time 3 setting 
00:00 
* Below, 7 and 8 are for the wait function setting, i.e., effective when 4 is selected.    
7 
WZ4 
Wait zone 4 setting 
same as Wait zone 1 
0 
8 
WT4 
Wait time 4 setting 
00:00 
5.4  Common  parameter  setting  mode  SET  3 
SET03 
Name 
Setting content 
Initial value 
* Below, 1 and 2 are for the time signal function setting, i.e., effective when 1 is selected.     
1 
ONT1 
Time signal ON delay timer 1 
0:00 to 99:59 (hours:minutes) 
00:00 
2 
OFT1 
Time signal OFF delay timer 1 
0:00 to 99:59 (hours:minutes) 
00:00 
* Below, 3 and 4 are for the time signal function setting, i.e., effective when 2 is selected.   
3 
ONT2 
Time signal ON delay timer 2 
0:00 to 99:59 (hours:minutes) 
00:00 
4 
OFT2 
Time signal OFF delay timer 2 
0:00 to 99:59 (hours:minutes) 
00:00 
* Below, 5 and 6 are for the time signal function setting, i.e., effective when 3 is selected.    
5 
ONT3 
Time signal ON delay timer 3 
0:00 to 99:59 (hours:minutes) 
00:00 
6 
OFT3 
Time signal OFF delay timer 3 
0:00 to 99:59 (hours:minutes) 
00:00 
* Below, 7 and 8 are for the time signal function setting, i.e., effective when 4 is selected.    
7 
ONT4 
Time signal ON delay timer 4 
0:00 to 99:59 (hours:minutes) 
00:00 
8 
OFT4 
Time signal OFF delay timer 4 
0:00 to 99:59 (hours:minutes) 
00:00 