Use and Care Manual

4
1. Gas Caddy should be on the ground and in a vertical position. Keep nozzle
in contact with container to help prevent static electricity ignition of fuel vapors.
2. Twist the fill cap vent screw one turn counter-clockwise. This allows the tank
to vent and the fuel to flow smoothly.
3. Open ball valve
4. Insert hose nozzle into tank to be filled and squeeze handle.
5. When fuel transfer is complete, release the nozzle handle to stop fuel flow.
6. Close the ball valve.
7. Close the fill cap vent.
Caution: As a safety precaution, fuel should be drained from the dispensing
hose. One can empty the hose by: Tilting the tank to its horizontal position,
opening the ball valve, lifting the hose above tank level and opening the nozzle
valve to drain the fuel back into the tank.
Todd Gas Caddy Dispensing Instructions
For gravity feed refueling
Todd Gas Caddy Dispensing Instructions
For rotary hand pump refueling
1. Gas Caddy should be on the ground and in a vertical position. Keep nozzle
in contact with container to help prevent static electricity ignition of fuel vapors.
2. Twist the fill cap vent screw one turn counter-clockwise. This allows the tank
to vent and the fuel to flow smoothly.
3. Open ball valve
4. Insert hose nozzle into tank to be filled, squeeze handle and crank pump.
5. When fuel transfer is complete, release the nozzle handle to stop fuel flow.
6. Close the ball valve.
7. Close the fill cap vent.
Warning: The Caddy should never be placed in a horizontal position with the
pump attached as the pump seals will allow fuel leakage.