User's Manual
Table Of Contents
- 1 Introduction
- 2 Safety
- 3 Overview of the Tobii Dynavox I–12+ and I–15+
- 4 Batteries in the Tobii Dynavox I-Series+
- 5 Using the Tobii Dynavox I-Series+
- 5.1 Starting the Device
- 5.2 Shutting Down the Device
- 5.3 Using Gaze Interaction
- 5.4 Using Windows Control
- 5.5 Wake the Tobii Dynavox I-Series+ from Sleep with Gaze Interaction
- 5.6 Pause/Resume Gaze Interaction and Put the Tobii Dynavox I-Series+ to Sleep with Gaze Interaction
- 5.7 Using the Cameras
- 5.8 Using the GEWA Programmable IR Remote Control
- 5.9 Adjusting the Volume
- 5.10 Adjusting the Sound
- 5.11 Performing a Factory Recovery
- 5.12 Calibrating the Touch Screen
- 6 Configuring the Tobii Dynavox I-Series+ with the I-Series Control Center
- 7 Gaze Interaction Settings
- 8 Gaze Selection Settings
- 9 Product Care
- Appendix A Support, Warranty, Training Resources
- Appendix B Compliance Information
- Appendix C Computer Device States of Operation
- Appendix D Maximum Allowed Temperature
- Appendix E Technical Specifications
- Appendix F Approved Accessories
7.2.5 Removing Calibration Point(s)
If there is a calibration point that is consistently bad after calibration (the green lines are scattered all around and outside the
circle of the calibration point) you can remove that point completely from the calibration, this may improve the calibration of the
other points. Be aware that if you remove a point, that area of the screen will be uncalibrated and Gaze Interaction will not func-
tion properly there.
To remove one or more calibration points, follow these steps:
1. Open Gaze Interaction Settings > Calibration.
2. Select the point(s) you want to remove under Calibration Result.
3. Select the Remove Point(s) button.
7.2.6 Customizing the Calibration
To customize the calibration, follow these steps:
1. Open Gaze Interaction Settings > Calibration.
2. Select the Settings... button
General
3. Select calibration background by selecting the background color button and select the desired color.
4. Specify the number of points you want to calibrate with (two, five or nine) from the Calibration points drop down list.
The higher number of points, the more accurate the calibration.
5. Select if you want to have sound feedback or not from the Sound feedback drop down list.
Stimulus
6. Select the stimulus type from the Stimulus type drop down list. There are three types available, each with different cus-
tomizing options:
• Dot:
– Select color of the dot by selecting the Stimulus color button.
– Select size of the dot by selecting from the Stimulus size drop down list.
– Select speed of the dot by selecting from the Stimulus speed drop down list.
• Image:
64