3.  Electrical Connections: 
  FREE STANDING UNITS: All  free  standing  hot  food  servers  are  quipped  with  a  factory  installed  36” 
(914mm) cord and plug.
  • 120V models: Plug conforms to NEMA Standard 5-15P 
• 208/240V models: Plug conforms to NEMA
 Standard 6-15P
  BUILT-IN UNITS: Most units are provided with a 48” exible metal conduit for electrical connections 
(see electrical specications for specics). 
D. Installation of Built-In Units: 
All of these units are true built-in models and are designed to be installed into the front face of a counter xture.  
Front of units extends beyond the body to form a self-trimming ange that covers the cut out in the xture.
1.  Cabinet Cut Out and Support.  Cut out the face of the counter xture according to the drawing that is 
provided with your hot food server.  Figure 2-5 can also be used for the cut out drawing of your model 
number. As shown in the drawing allow 1/2” (13mm) minimum cabinet face material above top of cut out 
opening. This allows unobstructed seating of hot food server ange.
  Be sure 
counter xture has adequate depth from front face to inside of back to accept the hot food server. 
Minimum depths are shown for each model in Figure 2-5.
a.  The 
hot food server body must  be  supported from the bottom.  This can be accomplished by 
installing metal support angles of wooden support blocks as shown in Figure 2-5.  The supports 
are not supplied and must be furnished using a suitable strength metal or wood.  The top surface 
of these supports must be 1/16” (3mm) below the bottom edge of the face cut out.  A metal or 
wood crossbrace approximately 2-1/2” (64mm) wide should be securely mounted between the 
supports as shown.  The center line of the crossbrace must be 4” (102mm) from the face of the 
cut out and its top surface must be ush with the side supports.
b.  An 
alternate  support  method  is  to  install  a  solid  at  platform  in  lieu  of  the  side  supports  and 
crossbrace. The top surface of the platform must be 1/16” (3mm) below the bottom edge of the 
cut out.
INSTALLATION continued
B
A
C
1/2” Minimum
Cut Opening for 
Hot Food Server
1/2” Minimum
IL2090-01
Figure 2-5, Cabinet Mounting
BUILT-IN MODELS OPENING DIMENSIONS
Model “A” Width “B” Height “C” Depth
3A20A
23 3/8” 594 mm
11 1/2” 292 mm
24 1/2” 622 mm
3B20A 22 3/4” 578 mm
3A80A
29 3/8” 746 mm
11 1/4’ 286 mm 20 5/8” 524 mm
3B80A 21 3/4” 552 mm
20 3/4” 527 mm
3C80A 29 1/2” 749 mm
3B84A 22” 559 mm
3C84A 32 3/4” 832 mm
2.
  I
nstall Leveling Feet (shown 
below).    Open  the  top  drawer 
and remove the small cloth bag 
containing  four  hex  head  cap 
screws & two mounting screws.  
Thread these four screws hand 
tight  up  into  the  four  holes  in 
the bottom of the unit.  Refer to 
2-6.
IL2100
Right: Leveling Feet for 
Built-in Units. 
(pn: 2C-1513D8805)