Datasheet

13
- GB -
7 Wear parts
Impeller (20) and foam filters (7) are wearing parts and are, therefore, not covered by our warranty.
8 Storage/Over-wintering
Remove the unit at temperatures below zero degrees centigrade. Clean the unit thoroughly, check for
damage and store immersed in a frost-free environment. Ensure that the power plug is not flooded.
9 Remedy of faults
Malfunction Cause Remedy
No mains voltage Check mains voltage The unit does not switch on
Air in the pump housing Pull the power plug; for venting, tilt the unit
towards the skimmer flap
Impeller blocked Clean Insufficient delivery rate
Filter basket soiled Clean
Air hose kinked or disconnected Ensure secure fastening and avoid kinks in
the air hose
No aeration
The air hose is not inserted up to the mark in
the intake socket
Correctly position the air hose in the intake
socket
Water temperature too high Note maximum water temperature of +35° Unit switches off after a brief running time
(approx. 10 s)
Pump run dry Clean pump and unit For switching on again,
pull the power plug and reinsert in the socket
The unit floats up Filter basket full or clogged Switch off the unit and clean filter basket
Unit floats up, pump is switched on Impeller soiled Switch off the unit and clean impeller
10 Disposal
Dispose of the unit in accordance with the national legal regulations.
11876-07-13_GAW_SwimSkim CWS.pdf13 13 01.08.2013 14:04:46