Storage/Over-wintering
• Put the unit out of operation at water temperatures below 8 °C or, at the latest, when freezing temperatures are to
be expected.
• Drain and thoroughly clean the unit, check for damage.
• Remove, clean, dry and store all filters in a frost-free environment.
• Ensure that the storage place is inaccessible to children.
• Cover the filter container such that the ingress of rain water is excluded.
• Drain all hoses, pipes and connections as far as possible.
Wear parts
The UVC lamp, the quartz glass and the filters are wear parts and are excluded from the warranty.
Disposal
Do not dispose of this unit with domestic waste! For disposal purposes, please use the return system provided.
Disable the unit beforehand by cutting off the cables.
Only dispose of the UVC lamp by using the return system provided for this purpose.
Remedy of faults
Malfunction Cause Remedy
The unit performance is not satisfactory Unit has been in operation only for a short time The complete biological cleaning effect is only
achieved after several weeks
Water extremely soiled Remove algae and leaves from the pond,
change the water
Excessive fish and animal population Guide value: approx. 60 cm fish length in 1 m³3
pond water
Foam filters soiled Clean filters
Quartz glass tube soiled Remove UVC and clean quartz glass
UVC lamp capacity exhausted Replace the lamp after approx. 8,000 operating
hours
UVC lamp display is not lit Power supply of Filtoclear-UVC not connected Connect UVC power plug
UVC lamp defective Replace the UVC lamp
Connection defective Check electrical connection
UVC overheated UVC automatically switches on when cooled
down
No water outlet from the pond inlet Pump power supply not connected Connect pump power supply
Pond inlet blocked Clean pond inlet
Filter container/pump housing clogged Clean filter container/pump housing