Installation
Attention! Dangerous electrical voltage.
Possible consequences: Death or serious injuries.
Protective measures:
Only operate the unit with the protection hood fitted.
Ensure that the unit is installed water-tight with a safety distance from the water of a minimum of 2 m.
Install the unit so that it is not exposed to direct sun radiation (max. 40 ºC).
How to proceed:
B
Place the pressure filter in a flood protected position at a distance from the pond edge of at least 2m on firm and
level ground.
As an alternative, the filter can also be partly buried up to approx. 5 cm below the closing clamps.
The height difference between the filter lid and the free outlet point may be max. 2 m.
Ensure unrestricted access to the cover to be able to carry out work on the unit.
Start-up
Attention! Dangerous electrical voltage.
Possible consequences: Death or severe injury.
Protective measures:
Electrical units and installations with a rated voltage of U > 12 V AC or U >30 V DC located in the water:
Isolate the units and installations (switch off and disconnect from the power supply) before reaching into
the water.
Isolate the unit before starting any work.
Secure the unit to prevent unintentional switching on.
Attention! Never operate the unit with a water pressure of more than 0.2 bar!
How to proceed:
C
Important:
Switch the pump on first, then the UVC clarifying unit.
Do not operate the unit without water flowing through.
The unit switches on automatically when power connection is established.
Switching on: Connect power plug to the socket.
The control lamp is lit.
The flow indicator flap in the transparent stepped hose adapter in the outlet moves.
Note:
After a new installation, the unit only reaches its full biological cleaning effect after a few weeks.
The full effect on bacteria is only reached as from a water temperature of + 10 °C.
In the event of overheating, the installed temperature monitor switches the UVC lamp off automatically, the lamp
automatically switches on again once cooled down.
Check all connections for leaks.
Switching off: Disconnect the power plug.