15.3.3. Output mute control
Assign the Mute ON/OFF function to the Pin.
Notes
Output mute control is only available to the DP-SP3 unit targeted by the contact input.
Group the output channels, then perform controls in groups.
When “Pulse” is selected for the control method, even if the unit’s power is switched off, the output mute state
can be recalled when the power is switched on again.
The output mute cannot be reset using the contact input for the channel of which output mute is set to ON with
the DP-SP3 PC Software.
Step 1. Set the mode to [Direct].
Step 2. Set the function to [Mute].
Step 3. Set the control to either [Make] or [Pulse].
Step 4. Select the target channel to which mute control function is assigned.