9000 Series Mixer/Amplifiers RS-232C Protocol Manual Ver.3.
TABLE OF CONTENTS Page# 1. SUMMARY…………………………………………………………………….... 3 2. SERIAL PORT SETTING…………………………………………………….... 3 3. COMMAND CONFIGURATION………………………………………………. 4 4. TRANSMISSION DATA AFTER COMMAND RECEPTION……………….. 4 5. CONTROL COMMAND AND SETTING VALUE……………………………. 5 5.1. Channel Fader Gain……………………………………………………………. 5 5.1.1. Channel Fader Gain - Position setting…………………………………… 5 5.1.2 Channel Fader Gain - Step Up/ Step Down…………………………….…. 7 5.2. Crosspoint Gain………………………………………………………………… 9 5.3.
1. SUMMARY The RS-232C protocol described in this document is designed to be used to control the 9000 Series Amplifier from a PC and/or remote controller. This specification applies to the 9000 Series firmware version 3.13 or later.
3. COMMAND CONFIGURATION • Command • Command Data length (N) Data 1 Data 2 Data N is in the range of 80H to FFH. and are in the Data length range of 00H to 7FH. Data • Data length (N) refers to the length of the subsequent data of Data 1 to Data N. • If received data contains more byte data than the Data length, these exceeding data are abandoned. • If a next command received contains byte data shorter than the Data length, the previous command is abandoned. 4.
. CONTROL COMMAND AND SETTING VALUE 5.1. Channel Fader Gain 5.1.1. Channel Fader Gain - Position setting Set the input and output channel fader gains to a fixed value position. Note: Command cannot be received during power off. 9000Series Amplifier responds with the same data as that received.
CHANNEL FADER GAIN - POSITION V/S GAIN TABLE Position HEX DEC 00H 0 01H 1 02H 2 03H 3 04H 4 05H 5 06H 6 07H 7 08H 8 09H 9 0AH 10 0BH 11 0CH 12 0DH 13 0EH 14 0FH 15 10H 16 11H 17 12H 18 13H 19 14H 20 15H 21 16H 22 17H 23 18H 24 19H 25 1AH 26 1BH 27 1CH 28 1DH 29 1EH 30 1FH 31 20H 32 21H 33 Gain (dB) -∞ -70.0 -68.0 -66.0 -64.0 -62.0 -60.0 -59.0 -58.0 -57.0 -56.0 -55.0 -54.0 -53.0 -52.0 -51.0 -50.0 -49.0 -48.0 -47.0 -46.0 -45.0 -44.0 -43.0 -42.0 -41.0 -40.0 -39.5 -39.0 -38.5 -38.0 -37.5 -37.0 -36.
5.1.2 Channel Fader Gain - Step Up/ Step Down Set the input and output channel gain positions by the number of steps. Positions can be varied from the current status by the designated number of steps. One position varies per step. 9000 series Amplifier informs position values changed by commands. Position values are shown in POSITION V/S GAIN TABLE. Values are 1dB step under -40dB, and 2dB step under -60dB. The 9000series Amplifier informs position values changed by Step Up or Down.
CHANNEL FADER GAIN – STEP UP / STEP DOWN TABLE Step Up HEX DEC 41H 65 42H 66 43H 67 44H 68 45H 69 46H 70 47H 71 48H 72 49H 73 4AH 74 4BH 75 4CH 76 4DH 77 4EH 78 4FH 79 50H 80 51H 81 52H 82 53H 83 54H 84 55H 85 56H 86 57H 87 58H 88 59H 89 5AH 90 5BH 91 5CH 92 5DH 93 5EH 94 5FH 95 Gain (dB) +0.5 step +1.0 step +1.5 step +2.0 step +2.5 step +3.0 step +3.5 step +4.0 step +4.5 step +5.0 step +5.5 step +6.0 step +6.5 step +7.0 step +7.5 step +8.0 step +8.5 step +9.0 step +9.5 step +10.0 step +10.5 step +11.
5.2. Crosspoint Gain Set the crosspoint switch gain. 9000Series Amplifier responds with the same data as that received. This command is enabled when in the mixer mode only. Note: Command cannot be received during power off.
CROSSPOINT GAIN TABLE value HEX DEC 00H 0 01H 1 02H 2 03H 3 04H 4 05H 5 06H 6 07H 7 08H 8 09H 9 0AH 10 0BH 11 0CH 12 0DH 13 0EH 14 0FH 15 10H 16 11H 17 12H 18 13H 19 14H 20 15H 21 16H 22 17H 23 18H 24 19H 25 1AH 26 1BH 27 1CH 28 1DH 29 1EH 30 1FH 31 20H 32 21H 33 Gain (dB) -∞ -70.0 -69.0 -68.0 -67.0 -66.0 -65.0 -64.0 -63.0 -62.0 -61.0 -60.0 -59.0 -58.0 -57.0 -56.0 -55.0 -54.0 -53.0 -52.0 -51.0 -50.0 -49.0 -48.0 -47.0 -46.0 -45.0 -44.0 -43.0 -42.0 -41.0 -40.0 -39.0 -38.0 Value Gain (dB) HEX DEC 22H 34 -37.
5.3. Preset Memory Recall Recalls any desired preset memories. 9000Series Amplifier responds with the same data as that received. Note: Settings to be stored in preset memories are referred to as “SCENE” in mixer mode and “EVENT” in matrix mode. Preset Memory Recall command cannot be received during power off.
5.4. Channel ON/OFF This performs ON/OFF setting of the Input or Output channel. 9000Series Amplifier responds with the same data as that received.
5.6. Tone Control Performs Bass and Treble gain settings of the input/output channels. 9000Series Amplifier responds with the same data as that received.. Note: Command cannot be received during power off.
TONE CONTROL GAIN POSITION TABLE Value Gain (dB) HEX DEC 00H 0 -12.0 01H 1 -11.0 02H 2 -10.0 03H 3 -9.0 04H 4 -8.0 05H 5 -7.0 06H 6 -6.0 07H 7 -5.0 08H 8 -4.0 09H 9 -3.0 0AH 10 -2.0 0BH 11 -1.0 0CH 12 0 Value Step Down HEX DEC 21H 33 -1.0 step 22H 34 -2.0 step 23H 35 -3.0 step 24H 36 -4.0 step 25H 37 -5.0 step 26H 38 -6.0 step 27H 39 -7.0 step 28H 40 -8.0 step 29H 41 -9.0 step 2AH 42 -10.0 step 2BH 43 -11.0 step 2CH 44 -12.0 step Value Gain (dB) HEX DEC 0DH 13 +1.0 0EH 14 +2.0 0FH 15 +3.0 10H 16 +4.
5.7. EQ Settings Perform EQ settings (ON/OFF, Band number, Gain, Q and Center frequency) of the input/output channels. 9000Series Amplifier responds with the same data as that received. Band number, Gain, Q, and Center frequency cannot be received when EQ is set to OFF. They can be valid only when EQ is set to ON. Note: Command cannot be received during power off.
EQ-Q TABLE Value Q HEX DEC 00H 0 0.3 01H 1 0.5 02H 2 0.7 03H 3 1 04H 4 1.5 05H 5 2 06H 6 3 07H 7 5 EQ-FREQUENCY TABLE Value Freq (Hz) Value Freq (Hz) HEX DEC HEX DEC 00H 0 20 11H 13 1k 01H 1 25 12H 14 1.25k 02H 2 31.5 13H 15 1.6k 03H 3 40 14H 16 2k 04H 4 50 15H 17 2.5k 05H 5 63 16H 18 3.15k 06H 6 80 17H 19 4k 07H 7 100 18H 20 5k 08H 8 125 19H 21 6.3k 09H 9 160 1AH 22 8k 0AH 10 200 1BH 23 10k 0BH 11 250 1CH 24 12.
5.8. Loudness Compensation Settings Perform loudness compensation settings of the Input / Output channels. 9000Series Amplifier responds with the same data as that received. Note: Command cannot be received during power off.
5.9. Filter Settings Perform Filter (HPF/LPF) settings of Input / Output channels. 9000Series Amplifier responds with the same data as the receipt. Note: Command cannot be received during power off.
5.10. Input Sensitivity Setting Performs input sensitivity setting of Input channel. 9000Series Amplifier responds with the same data as that received. Input sensitivity setting is enabled only for the channel on which the D-001T or AN-001T is used. Note: Command cannot be received during power off.
6. Channel Name Request Reads input and output channels’ names. The 9000 Series Amplifier responds with the channel name to this command. F0H, 03H, 40H, , 00H: Input channel 01H: Output channel 00H - 07H (Input channel 1 - 8) 00H - 07H (Output channel 1 - 8) Example: Acquiring the Input Channel 1’s name. F0H, 03H, 40H, 00H, 00H Response data are provided below.
7. Speaker Preset Setting Recalls speaker EQ preset values for specific TOA model speakers. 9000Series Amplifier responds with the same data as that received. Note: Command cannot be received during power off.
8.
9. COMMUNICATION EXAMPLES Command Controller Channel fader gain Input ch1 Fader gain=0dB 91H, 03H, 00H, 00H, 6AH Input ch1 Fader gain 1 step 93H, 03H, 00H, 00H, 41H up A-9000 Response 91H, 03H, 00H, 00H, 6AH 93H, 03H, 00H, 00H, 6CH (Amplifier response of +1dB Input Channel 1 fader gain after command.
Command Input ch1 Insense -24dB Output ch2 SpPreset F-122 Input ch3 Phantom ON Input ch1 Name “INPUT1” Controller Input sensitivity setting ACH, 02H, 00H, 02H Speaker preset setting ADH, 02H, 01H, 01H Phantom power setting 87H, 02H, 02H, 01H Channel name recall F0H, 03H, 40H, 00H, 00H Page 24 of 24 A-9000 Response ACH, 02H, 00H, 02H ADH, 02H, 01H, 01H 87H, 02H, 02H, 01H C0H, 09H, 00H, 00H, 49H, 4EH, 50H, 55H, 54H, 31H, 00H