Product Manual
6
11. The damper stop prevents unwanted air infiltration through either fan. The Damper stop can be adjusted so the damper does not
swing open into the house by wind or a negative pressure in the house. IMPORTANT: The damper stop prevents the damper from
swinging inward and should not be used if using the XCHANGER fan to bring outside air in. With the damper stop pushed all the
way forward, the damper will swing both ways. With the damper stop pulled all the way back, the damper will only swing to the
outside. Use the damper stop only if you want to block air infiltration into the house during seasons when the XCHANGER is not
being used or when using the XCHANGER to exhaust air. .
12. WARNING: Unplug fans from dehumidistat control when changing direction to prevent damage or injury. Insert fans in desired
direction for either exhaust or intake. See arrow on bottom of fan cartridge or side of fan shroud for air flow direction. Once
installed confirm the air is being exhausted or supplied depending upon application, (See Diagram O).
13. Insulate around XCHANGER housing, (See Diagram P). IMPORTANT: Use of expanding foam on top of XCHANGER case may
interfere with damper slides on top of XCHANGER case. Make sure damper slides move freely.
XCHANGER DEHUMIDISTAT CONTROL MODULE INSTALLTION & OPERATION
Install XCHANGER dehumidistat control module on wall with provided screws and
wall anchors and plug in XCHANGER fans into side outlets.
IMPORTANT: Do not plug other devices into dehumidistat control or damage may result.
Once fans are installed in XCHANGER, plug in dehumidistat control into standard outlet.
The XCHANGER control module includes an adjustable dehumidistat control which acti-
vates the fan(s) if the relative humidity rises above the selected set-point. The dehumidis-
tat can be turned fully clockwise to the ‘on’ position for constant fan(s) operation or it can
be turned fully counter-clockwise to ‘off’ during seasons or times when it is not desired
for the XCHANGER fan(s) to run. Each XCHANGER fan is independently controlled by
its own on/off switch. To inhibit mold growth it is recommended that the Relative Humidity
(RH) be below 60%. Turn switch(s) off during seasons or applications where it is not desired to run that fan, (See Diagram Q).
XCHANGER LADDER DIAGRAM
DIAGRAM N
DIAGRAM O
THE DAMPER WILL SWING BOTH WAYS WITH THE
DAMPER STOP PUSHED FORWARD, THE DAMPER
WILL ONLY SWING TO THE OUTSIDE WITH THE
DAMPER STOP PULLED ALL THE WAYS BACK.
DIAGRAM Q
SCREW DEHUMIDISTAT CONTROL TO WALL AND
PLUG IN FANS INTO SIDE OUTLETS.
WARNING: UNPLUG FANS WHEN CHANGING
DIRECTION. SEE ARROW ON BOTTOM OF FAN
CARTRIDGE OR SIDE OF FAN SHROUD FOR
AIR FLOW DIRECTION.
DIAGRAM P
INSULATE AROUND XCHANGER HOUSING.
120 VAC
50/60 Hz
DE-HUMIDISTAT
CHANGE CONTROL BOX
HOT BLACK
WHITE
8050022
BLUE
NEUTRAL BLACK
BLUE
RED
RED
RED
RED
RX
SWITCHED OUTLETS
FAN SWITCH 2
FAN SWITCH 1
XCHANGER FANS
IMPORTANT:
ONLY PLUG
XCHANGER FANS
INTO CONTROL!
ON/OFF
SWITCHES