Draft and Exhaust Application Guide DRAFT APPLICATIONS INDUCER MODEL Multiple &/or Modulating Power Burner/Fan Assisted Heaters RT750 OR RT1500 Multiple Atmospheric Heaters with Flue Dampers CONTROLS Gas Heaters with Draft Hoods or Draft Diverters Gas Fireplace Gas Oven Oil Heater Single Gas Power Burner RT750 OR RT1500 Both Include PSA-1 Fan Prover RT750H OR RT1500H Solid Fuel Stove, Fireplace, Oven EXHAUST APPLICATIONS OPTIONAL ACCESSORIES **ABD-Series Balancing Baffle DH750 or DH1500 Discharg
RT-Series Typical Applications Exhaust COP (XCOP1) Draft COP (DCOP1) 1) Intercepted call for heat activates Draft COP. Triggered by an external switch or constantly operating, the Exhaust COP maintains a negative exhaust pressure set point by modulating the speed of the Rooftop Inducer to meet demand. 2) Draft is measured and compared to set point. 3) Inducer ramps up to meet draft set point. 4) PSA-1 fan prover closes enabling burner call circuit.
Selection Guide for Gas & Oil Applications Models RT750 & RT1500 Tile Lined Chimneys RT750 Series clamps to rectangular tile liners 6” x 6” through 10” x 14” and round tile liners from 6”-11”. RT1500 Series clamps to rectangular tile liners 8” x 8” through 12” x 14” and round tile liners from 10”-14”. MODEL VENT PIPE DIAMETER* RT750 8" RT750 10" RT1500 12" RT1500 14" BTU/HR. INPUT, GAS WITH DRAFT HOOD/DIVERTER BTU/HR. INPUT, GAS/OIL WITH BAROMETRIC CONTROL MAX.