User's Manual
- 21 -
User’s manual_v01
Table 2 - 4 Pin description/ EXTERNAL NFPA ALARM
2.2.3 NAMEPLATE WITH UL MARK
It shows the basic information of PSR, such as product model number, frequency range, gain & power, and
UL/FCC approved marks.
Figure 2 - 5 Nameplate
A Normal AC Power_Normal Open
B Loss of normal AC Power_Normal Open
C Battery charger failure_Normal Open
D Low battery capacity (70%)_Normal Open
E Donor antenna malfunction_Normal Open
F Active RF emitting device malfunction_Normal Open
G System component malfunction_Normal Open
H NC
J Normal AC Power_Normal Close
K Normal AC Power_Common
L Loss of normal AC Power_Normal Close
M Loss of normal AC Power_Common
N Battery charger failure_Normal Close
P Battery charger failure_Common
Q Low battery capacity (70%)_Normal Close
R Low battery capacity (70%)_Common
S Donor antenna malfunction_Normal Close
T Donor antenna malfunction_Common
U Active RF emitting device malfunction_Normal Close
V Active RF emitting device malfunction_Common
W System component malfunction_Normal Close
X System component malfunction_Common
Y EXT Shutdown Alarm
Z GND
EXT, Alram
MS3102E_24-28