User's Manual
- 16 -
User’s manual_v01
1.4 Frequency diagram
Frequency bands of PSR series can be configured and operated separately for the three different bands, FirstNet,
PS700 and PS800.
There are 2 different class types of the device as defined in FCC Part 90, Signal Booster classifications.
Each frequency band is shown below.
Class A
Available frequency ranges ;
Not available @ FirstNet
769~775/ 799~805MHz @ PS700
851~869/ 806~824MHz @ PS800 (861-869MHz : For IC only)
Available CH bandwidths ;
6.25/ 12.5/ 25/ 50/ 75kHz
Class Bq
Available frequency ranges ;
758~768/ 788~798MHz @ FirstNet
769~775/ 799~805MHz @ PS700 (For FCC only)
851~861/ 806~816MHz @ PS800 (For FCC only)
Available CH bandwidths ;
5/ 10 MHz @ FirstNet
100/ 200kHz @ PS700, PS800
FirstNet
10MHz 6MHz
PS700
Class A only
Class A
PS800
Class A only
18MHz
758
788
769
799
775
805
768
798
851
806
869
824
861
816
862
817
17MHz
Commercial
PS800
Class B only
10MHz 7MHz
FirstNet
LTE 5M or 10M only
10MHz 6MHz
PS700
Class B only
Class B
758
788
769
799
775
805
768
798
851
806
869
824
861
816
862
817
Figure 1 - 4 Frequency diagram