2.2.7 RF port
Figure 2 - 10 RF ports
The RF connections are made via two 4.3-10 mini-DIN female connectors.
The RF connector labeled “DONOR” must be connected to the antenna towards BTS side. The DONOR port can
receive both 700 and 800MHz public safety signals. The RF connection labeled “SERVICE” must be connected
to the antenna facing the area to be covered by PSR.
Available RF power coupling is -30dB.
2.2.8 Grounding
The grounding terminal is located at the lower both side of PSR, and can support a ground cable up to
1.25mm² (16AWG) in diameter and should be permanently connected to a grounding bar.
The grounding cable should be properly connected before powering on the equipment, by using ground cable
contained in the box.
Figure 2 - 11 Ground Cable Terminal