- 2V - 2V +5V +5V + 2V + 2V G D + ZEUS Access Front Panel Interface for ZEUS Studio Bus V 1.
ZEUS Access + The Zeus Access provides an easy way of linking an external power supply to the Zeus Power System using just 2HP of space. Together with the Zeus Studio Bus board and a few simple steps, you can now power up a modular system with ease! Residing on the left-most side of your case, the Zeus Access supplies a convienent interface to easily power the Zeus Powered Bus Board system from the external Cincon-TTA laptop-style universal power supply.
ZEUS Access The Access is fully compatible with the Cincon-TTA Universal Power Supply, a power supply that we custom made together with Cincon Taiwan for powering the Zeus Studio Bus System. These supplies can be used with mains voltages from 100 to 220V without the use of a transformer, only the proper country outlet plug adapter.
ZEUS Access Installation: Prior to starting, please view the wiring diagram on the next page to get an understanding of the entire process. Push down the lever on the Zeus Studio Bus using a small flat screw driver or your finger and insert the Green lead to the “GND”, let go of the lever and the wire will be locked. Do the same as above, this time insert the Red lead to the “+15V”, let go of the lever and the wire will be locked. Make sure both leads are fully inserted into the terminal holes.
+ - N +15V GND 0 Wiring Diagram for One Zeus Studio Bus Board ZEUS Access +5V +12V +5V +12V GND 12V 12V
+ - +15V GND C 0 0 Wiring Diagram for Two Zeus Studio Bus Boards ZEUS Access +5V +5V +5V +12V +5V +12V GND 12V 12V GND 12V +12V 12V +12V