User Manual
21
E
N
G
L
I
S
H
5. Above the regulator where the barrel is inserted into the marker body use a hex wrench
to remove the screw, freeing the regulator from the body.
6. Lastly disconnect the exible hose from the quick disconnect tting by squeezing the
tting towards the regulator and then pull the hose out of the tting.
7. You can now slide the regulator down out of the bottom of the foregrip.
Regulator Disassembly and Maintenance
Regulator maintenance should be performed every 50,000 – 70,000 shots or if there is an
issue.
1. Remove the regulator as described in the Removal of Grip Frame and Regulator
section on the previous page.
2. At this point you can access the regulator piston of the regulator by unscrewing the top
half from the bottom half of the regulator.
3. To get the brass piston out, tap the regulator gently on your hand until the piston falls
out of the regulator body.
4. To perform maintenance on the regulator, you should apply silicon based grease (Dow
33 or similar) to the regulator piston O-ring and shaft. Be sure when reassembling the
regulator to place the spring washers in the correct orientation:
LARGE END OF PISTON )()()() SMALL END OF PISTON.
Further disassembly of regulator is only necessary should the regulator be leaking or
the pressure of the regulator is not remaining stable. See section Advanced Regulator
Disassembly & Maintenance
on page 22.