Data Sheet

www.tinysine.com
Reference voltage is 3.3V, only used in HM-10.
3. Query module MAC address
Send
Receive
Parameter
AT+ADDR?
OK+ADDR:MAC Address
None
4. Query/Set Advertising type
Send
Receive
Parameter
AT+ADTY?
OK+Get:[para]
None
AT+ADTY[para]
OK+Set:[para]
para:0~3
0:Connect by any device
1:Allow to connect with last
succeeded device(within
1.28s after power on)
2:Allow to broadcast and
scanning
3:Only advertising
Default:0
Added since V519 version
5. Query/Set ANCS switch
Send
Receive
Parameter
AT+ANCS?
OK+Get:[para]
None
AT+ANCS[para]
OK+Set:[para]
para: 0, 1
0: Off
1: On
NOTE: 1. Must execute AT+TYPE3 first
2. Please send AT+RESET to restart module if you set value 1
3. Added in V524 version
6. Query/Set whitelist switch(only allow 3 mac address link to module)