Data Sheet

www.tinysine.com
72. Query/Set Module Bond Mode
Send
Receive
Parameter
AT+TYPE?
OK+Get:[para]
None
AT+TYPE[para]
OK+Set:[para]
para: 0~2
0: Not need PIN Code
1: Pair not need PIN
2: Pair with PIN
3: Pair and bond
Default: 0
NOTE: If your module version is less than V515, please don’t use this command. Under
android 4.3 AT+TYPE1 is same as AT+TYPE2. TYPE3 is added in V524 version.
73. Query/Set service UUID
Send
Receive
Parameter
AT+UUID?
OK+Get:[para]
Para: 0x0001~0xFFFE
Default: 0xFFE0
AT+UUID[para]
OK+Set:[para]
Added since V518 version. Need to re-power module.
e.g.
Change UUID value to 0xAAA0
Send: AT+UUID0xAAA0
Receive: OK+Set:0xAAA0
74. Query/Set UART sleep type
Send
Receive
Parameter
AT+UART?
OK+Get:[para]
para: 0, 1
0: When module goes into
sleep mode, you can wake
up module through UART.
1: When module goes into
AT+UART[para]
OK+Set:[para]