Data Sheet
www.tinysine.com
Connect use MAC String:
AT+CON[MAC String]
28. Start a iBeacon device discovery scan
Send
Receive
Parameter
AT+DISI?
OK+DISCS
OK+DISC: [p1:p2:p3:p4:p5]
OK+DISCE
p1:Factory ID
p2:iBeacon ID
p3: Major Value
Minor Value
Measured Power
p4: MAC
p5: RSSI
Added since V309 version.
NOTE: Must set AT+ROLE1 and AT+IMME1 first.
p1 length is 8; p2 length is 32; p3 length is 10; p4 length is 12; p5 length is 4.
p3: Major Value(length 4); Minor Value(length 4); Measured Power(length 2).
If device not enable iBeacon function, p1, p2, p3 will fill with ‘0’.
29. Query/Set iBeacon deploy mode
Send
Receive
Parameter
AT+DELO[para]
OK+DELO[para]
para:1~2
1:Allowed to broadcast and
scanning
2:Only allowed to broadcast
Default: 0
Added since V521 version to replace AT+BUSHU command.