Data Sheet
www.tinysine.com
27. Query/Set iBeacon deploy mode
Send
Receive
Parameter
AT+DISC?
OK+DISCS
OK+DIS[para1]:[para2]
OK+DISCE
para1: C; 0~2
C: Common String
0~2: Address type
para2: S, E, [MAC String]
S: Start discovery
E: End discovery
MAC String:
Device MAC String
NOTE: Module must set AT+ROLE1, AT+IMME1 first.
e.g
Send: AT+DISC?
Receive: OK+DISCS
Receive: OK+DIS[para1]: 123456789012(discovered device address
information)
If AT+SHOW1 is setup, you will receive name information as fellows:
Receive: OK+NAME: XXX
After send name value, will send 2 extra ā\r\nā value ASCII byte.
Receive: OK+NAME: XXX
After send name value, will send 2 extra ā\r\nā value ASCII byte.
......(Before V535, max results is 6; since V535, no limit)
Receive: OK+DISCE
Connect use array index:
Connect to a discovered device: AT+CONN0......AT+CONN5