Cat.
General 1 The ProgramaSTAT TPT44 combines the elements of timeswitch and room thermostat in a single compact, economical and stylish unit. Back up is provided to retain programme information in the event of a power failure. The TPT44 controls the room temperature to a comfort level when required and to a set-back temperature at other times. It does this using an internal temperature sensor.
Installation 2 We recommend this unit be fitted by a qualified electrician. Install in accordance with wiring and current building regulations. Please read the instructions carefully. If in doubt, contact the Timeguard Helpline 020 8450 0515. The TPT44 underfloor heating controller is designed to fit onto either a BS4662 recessed single box or a BS5733 surface mount single box. The minimum box depth required is 32mm.
Temporary temperature override’. After a few seconds the Heating ON indicator will show. Wait for 1 hour for a wood under floor or up to 5 hours for an uninsulated concrete floor (the warm-up time for uninsulated concrete will be substantially reduced when the moisture has been driven out of the concrete during the first few heating cycles) and feel if the floor starts to warm. If it does not, check the connections and carry out the checks on the mat or cable installation instructions.
Earthing The TPT44 itself does not require to be earthed. The screen around the flying lead (cold cable) from the Thermolay mat must be earthed to the box terminal. This also applies to the screen at each end of the Thermolay cable, both of which must be earthed in the same way. Programming 4 Power on and reset When first switched on the TPT44 has a default program set which is comfort mode from 7.00am to 10.30pm.
Heating ON Time dial – 30 minute segments Program mode Comfort mode Time Set-Back mode Manual mode 5 Temperature Floor limit Fig. 2 Time Setting 1. Press ‘Prog’ once, the time indicator now flashes, Program mode indicator ‘ ’ shows on the dial. 2. Press ‘+’ or ‘–’ to adjust the time. 3. Press ‘Set’ 5 times to exit, or wait 15 seconds for the unit to auto-exit to the normal run mode.
Program Setting 1. 2. 6 3. 4. 5. 6. Example: If you want to set 2 different programs, i.e. ON at 6am and OFF at 9.30am and then in the evening ON at 17.30 and OFF at 22.30. Press the ‘Prog’ button once and the time will start to flash. (In the Programming mode you will see a ‘ ’ on the top right hand side of the display, if there is no activity within 15 seconds the unit will exit the Programming mode and will start to run in the Normal Operating Mode). Press the ‘Set’ button once.
7. Wait 15 seconds until the screen has returned to Normal Operating Mode. Once you have done both programs you will see the segments highlighted which indicate the Comfort Temperature and the blank segments which indicate the Set Back Temperature. Note: The Time-Zone indicator is one segment on the time dial (24 hour clock). The time increases/decreases by 30 mins every time you press the ‘+’ or ‘–’ button. Temperature Settings 7 1. 2. 3. 4.
5. Press the ‘Set’ button once. You will see the ‘Ø’ symbol flashing which represents the Floor Temperature Limiter. 6. Using the ‘+’ or ‘–’ button, advance the temperature to 30°C (maximum). 7. Press the ‘Set’ button once to return to Normal Operating Mode. Manual Temperature Setting 8 A. Temporary temperature override. 1. Press ’+’ or ’–’. The ’ ’ indicator and the temperature flash. 2. Press the ’+’ or ’–’ key to set the temperature. 3.
Lock Function 1. Press and hold ’Set’ key for 5 seconds, ’Lock’ displayed, the keyboard lock is on. 2. Press and hold ’Set’ key for 5 seconds again, ’ULOC’ displayed, the keyboard lock is off. Read the Floor Temperature Press ’Set’ key once, the floor temperature is displayed and will go back to the air temperature after 5 seconds.
3 Year Guarantee In the unlikely event of this product becoming faulty due to defective material or manufacture within 3 years of the date of purchase, please return it to your supplier in the first year with proof of purchase and it will be replaced free of charge. For the second and third years or any difficulty in the first year telephone the helpline on 020 8450 0515. Note: A proof of purchase is required in all cases.
For assistance with the product please contact:- Helpline 020-8450-0515 or email helpline@timeguard.com For a product brochure please contact: Timeguard Ltd. Victory Park, 400 Edgware Road, London NW2 6ND Tel: 020-8452-1112 or email csc@timeguard.com A Group company 67.058.