Instruction Manual

8. Walk Test
Note: If the DIP Switch is set to the ON position, also make sure the
Slide Switch is set to the AUTO (middle) position.
Set the On-time adjuster fully anticlockwise to the min
10s position.
Set the Lux adjuster fully clockwise to the SUN symbol.
The light switch will now operate during the daytime as well as
at night, illuminating your lights for approx. 10 seconds each
time. This allows testing to be carried out to establish whether
the sensor is covering the required area.
Walk in front and around the sensor to establish the detection
area. The sensor will detect motion within an 10m diameter
(walking across), and within a 3m range (walking towards)
with the sensor mounted at 1m.
As you cross the detection ‘zone’ your lights will illuminate.
Now stand still until your lights extinguish (this should take
approx. 10 seconds).
Start moving again after 2 seconds until your lights turn ON.
Repeat the above, walking at various distances and angles from
the light switch. This will help you confirm the detection pattern.
6