Instruction Manual
Connection Diagram
7. DIP Switch and Slide Switch
Note: The DIP Switch located on the back of the light switch can be
used to enable or disable the Manual ON/OFF function, when using
the Slide Switch. By default this will be set ON.
• If the DIP Switch is set to the ON (upwards) position, the Slide
Switch can be used to turn your lights ON/OFF manually,
or can be set to AUTO for motion control only.
• If the DIP Switch is set to the opposite (downwards) position,
the Slide Switch will be disabled and your lights will turn ON
using motion only.
5
tion Diagram)
L 1L
X1 CAP.
In the event of ST910 not able to power on during installation
due to high impedance of LED lamp, installer is advised to
connect X1 capacitor (without polarity) in parallel with L/N.
Recommended X1 Capacitor value.
• X1 0.22uf / 275V or
• X1 0.33uf / 275V or
• X1 0.39uf / 275V