TLB98-Black/TLW99-White INSTALLATION & OPERATING INSTRUCTIONS 60W MULTI PIR BULKHEAD
SECTION ONE GENERAL INFORMATION The unit utilises passive infrared technology to detect heat radiation of moving human bodies. Upon detection, the lamp will illuminate for a user-determined time period. An integral daylight sensor ensures night-only operation. PARTS INCLUDED - Luminaire c/w PIR Sensor unit. - Instruction manual. Please keep safe for future reference. - 22W Compact Fluorescent Lamp - Accessory Pack. TOOLS & PARTS NEEDED - Electric/hand-held drill & bits.
SECTION THREE INSTALLATION After choosing a suitable location (see previous section) install the unit as follows: *** IMPORTANT *** Switch off the electricity at the fuse box by removing the relevant fuse or switching off the circuit breaker before proceeding with the installation. The unit is suitable for connection to a 230 V ac 50Hz electricity supply. It is suggested that 3-core round flexible cable of 1mm2 gauge is used. A isolating switch should be installed to switch the power to the unit ON & OFF.
The diagram below also shows the required connections for the addition of slave luminaires. When adding slaves, be sure not to exceed the maximum switchable load (see Technical Specifications). L1 N L N Isolation Switch L SECTION FOUR OPERATION AND TESTING WALK TEST PROCEDURE The sensor will rotate from left to right, and tilt forward or backward. Adjust the sensor to point in the required direction. (note diagram B) The unit can be set up in daylight or at night. The adjustment knobs are factory set.
The TIME setting controls how long the unit remains illuminated following activation and after all motion ceases. (See diagram E the time adjustment knob is indicated by the "Clock" symbol). The minimum time (fully anti-clockwise) is approx. 5 seconds, whilst the maximum time (fully clockwise) is approx. 5 minutes. Set the control to the desired setting between these limits. The DUSK control determines the level of darkness required for the unit to start operating.
Do not adjust this setting if you do not wish to use the Holiday Mode facility. This time adjustment is factory set to 1 hour. Please note: Fully anticlockwise is 1 hour, fully clockwise is 8 hours. After the defined period has elapsed, the unit will return to Automatic Mode and operate as previously set up. Holiday Mode will NOT reset to Automatic Mode at dawn, it will repeat each night until reset by the user.
SECTION SIX TROUBLESHOOTING GUIDE PROBLEM SOLUTION ❏ Lamp stays ON all the time at night. The unit may be suffering from false activation. Cover the sensor lens completely with a thick cloth. This will prevent the sensor from "seeing" anything. If the unit now switches off after the set time duration and does not reactivate, this indicates that the problem was caused by false activation. The problem may be solved by slightly adjusting the direction/angle of the sensor head (see previous section).
PROBLEM SOLUTION ❏ Unit activates during the daytime The level of ambient light in the area may be too dark for the current DUSK setting. During daylight, adjust the DUSK control slightly anti-clockwise. When the lamp load extinguishes, enter the detection area. If the PIR still activates, the setting is still too high. Repeat the above procedure until the PIR does not activate when you enter the detection area. Refer to previous section for more details.
TOP VIEW A 180º C SIDE VIEW 2.
E Dusk/Dawn Time Holiday Mode F Lens Mask Restrict long detection Restrict short detection Restrict RHS detection Restrict LHS detection
5 YEAR GUARANTEE In the unlikely event of this product becoming faulty due to defective material or manufacture, within 5 years of the date of purchase, please return it to your supplier with proof of purchase and it will be replaced free of charge. Should you encounter any difficulty please contact our helpline on 020 8450 0515.
Helpline 020-8450-0515 For a product brochure please contact: Timeguard Ltd. Victory Park, 400 Edgware Road, London NW2 6ND or email csc@timeguard.