Model: ETU17 Installation & Operating Instructions Compact 7 Day Timeswitch
ETU17 – Compact 7 Day Timeswitch Change Button Output Status showing Programme Button sets Day(s), Hours and unit either ON or OFF used to select the clock Minute times, selects/ time and the 6 ON/OFF cancels Random Mode programme times and to and self cancelling review them once set override Easy view 24 hour digital clock/timer display 1 Random Select Mode switches unit ON/OFF at random intervals between 10 & 30 minutes during programmed ON times giving the impression that your home or premises is alway
Battery: This product has a factory fitted rechargeable battery. If the ETU17 is left out of a live socket for more than 1 month the display may go blank. In this case plug into a live socket, wait four hours, and apply reset – see section 1 before programming. Programming Overview: 2 This is a seven day (weekly) timeswitch which has six programmes, each of which can be block programmed to work on all of the five weekdays, both weekend days, or all 7 days (24 hour operation).
Normal Operating Mode: In normal operation the ETU17 will display the correct day and its time with the colon flashing. The output status will be shown by either ON or OFF on the display. 1. To Reset Before Programming: 3 (To alter clock time or modify programmes – see section 5) To clear programmes from memory and reset the ETU17 press the and buttons together until the display goes blank (approximately 3 seconds).
Programming Sequence: Setting clock Programme 1 ON Programme 1 OFF Programme 2 ON Programme 2 OFF Programme 3 ON Programme 3 OFF Programme 4 ON Programme 4 OFF Programme 5 ON Programme 5 OFF Programme 6 ON Programme 6 OFF Operation Mode Note: Pauses between button presses greater than 1 minute during programming will result in automatic return to the operating mode. 4 2. Setting Clock (after reset): i. Day Setting – Press button to advance to the day required. Day 1 = Monday and Day 7 = Sunday.
to advance the minutes setting. For rapid minute selection press and hold down button. (Note: 16 hours shown as example of hours set) iv. Press button briefly – clock is now set and display shows ready for the first ON programme time. 3 To Set Programme ON/OFF Times (after clock setting): 5 It must be remembered that the ETU17 has a total of six programmes. i. The user is now able to set the day(s) that the first programme will operate on.
6 ii. Once the day option has been selected press button briefly to select hour time – display shows hour digits and ON flashing. Press button to advance hour setting. (Note: 2 days (Sat & Sun) shown as examples of days set.) iii. Minute Setting – Press the button briefly to select the minutes – display shows clock symbol and minute digits flashing. Press the button to advance the minutes setting. For rapid minute selection press and hold down button.
IMPORTANT After setting a clock time which falls within a programmed ON period, the unit will not switch ON. Press the button to switch the ETU17 ON (the ON will flash to indicate an override situation). After this the unit will operate normally to the programmes set. 4. Programme Review: 7 To fast review the set programmes or for quick exit to normal operating mode – press and hold down the button.
Having reached the clock time and day or programme time and day(s) requiring change, press the button briefly to initiate programme mode and then follow sections 2 and 3 as required. Having completed the change press and hold down the button until normal operating mode is reached and then release. 6. Cancelling Programmes: 8 Any ON/OFF programme can be cancelled by clearing its ON and OFF time separately.
8. Self Cancelling Override: To change the output status from ON to OFF or vice versa press the button whilst in normal operating mode. The output status will change and indicate override is in operation by flashing either the ON or OFF symbol on the display. The override will end at the next programmed change, or sooner, if the button is pressed again. 9.
Specifications: 10 i. Conforms to Directives: Conforms to the latest directives. ii. Permissible Loads: 13A resistive (heating) 5A inductive 1hp motor 500W low energy (compact fluorescent) and linear tube fluorescent lighting 1.5kW filament (incandescent) lighting. iii. Battery Back-up: 1000 hours by factory fitted rechargeable battery. iv. Operating Ambient Temperature Range: -10°C to 35°C. v. Operating Voltage: 230V AC. Not suitable for discharge lighting (e.g. SON and Metal Halide).
For assistance with the product please contact: HELPLINE 020 8450 0515 or email helpline@timeguard.com For a product brochure please contact: 67.058.04 (issue 3). Zerofour – November 2013 Timeguard Limited. Victory Park, 400 Edgware Road, London NW2 6ND Sales Office: 020 8452 1112 or email csc@timeguard.