User's Manual

UK Timecode Systems Ltd. Unit 6, Elgar Business Centre, Moseley Road, Hallow, Worcester.
WR26NJ. UK
Slave’s Attached Device Status
These commands should be used to get information regarding a device attached to a
slave unit, directly from the master device. There is one query to get static data that
rarely changes, and one to get data that can frequently change.
BLXS=n Get the slave device’s static data where n = slave’s BLink ID.
Returns a series of CSV fields that define the attached device and its capabilities.
The fields are returned comma delimited.
1. Blink ID
2. Manufacturer’s name - ASCII text value
3. Manufacturer’s model - ASCII text value
4. Capability Flags 32bit hexadecimal number See appendix
5. Storage unit #1 Name (ASCII string)
6. Storage unit #1 Capacity (integer value 0 - 65535)
7. Storage unit #1 Units 0 = Empty/Unknown,1 = KB, 2 = MB, 3 =
GB
8. Storage unit #2 Name
9. Storage unit #2 Capacity
10. Storage unit #2 Units
11. Storage unit #3 … etc.
BLXP=n Get the slave device’s changing data where n = slave’s BLink ID.
Returns a series of CSV fields denoting the attached devices current status
The fields are comma delimited.
1. Blink ID
2. Current transport status See appendix
3. Current frame rate numerator
4. Current frame rate denominator
5. Rate Flags (8bit Hex) Bit 0 = Drop Frame, others unused
6. Current battery level percentage
7. External power applied/battery charging flag
8. Current clip/file name
9. Storage unit currently selected or in use
10. Storage unit #1 media remaining time in minutes
11. Storage unit #1 media remaining size
12. Storage unit #2 media remaining time in minutes
13. Storage unit #2 media remaining size
14. Storage unit #3… etc.