Cut Sheet
OPERATION
The time delay begins when the supply voltage is applied.
Upon completion of the delay period, the internal relay will
energize, and remain that way until the supply voltage is
removed.
PIN CONNECTIONS
The Models 330 and 360 Operate Delay Timers require a
standard 8-pin socket for mounting, and use a standard
pin configuration. Refer to the pin diagram below, or on
the timer, for terminal connections.
An LED on top of the unit provides a quick visual indicator of
the relay’s status.
MODEL 330 / 360
Operate Delay Timers
READ ALL INSTRUCTIONS BEFORE INSTALLING, OPERATING OR SERVICING THIS DEVICE.
KEEP THIS DATA SHEET FOR FUTURE REFERENCE.
GENERAL SAFETY
POTENTIALLY HAZARDOUS VOLTAGES ARE PRESENT AT THE TERMINALS OF THE MODEL 330 OR 360.
ALL ELECTRICAL POWER SHOULD BE REMOVED WHEN CONNECTING OR DISCONNECTING WIRING.
THIS DEVICE SHOULD BE INSTALLED AND SERVICED BY QUALIFIED PERSONNEL.
Installation Instructions
TIME MARK is a division of
Telephone: Main - (918) 438-1220
Sales - (800) 862-2875
Fax: (918) 437-7584
E-mail: sales@time-mark.com
Internet: http://www.time-mark.com
Page 2 of 3 05/2014
© 2014
TIME MARK CORPORATION
11440 East Pine Street
Tulsa, Oklahoma 74116
Shows No Power Applied
DIMENSIONS - Model 360
DIMENSIONS - Model 330
LED Indicator Unit Status
Green Energized
Red De-energized
Flashing (Green or Red) Relay is Timing