User guide

2
V1.1 Page | 2 1070 Technical Manual
Contents
1. S pecification ..................................................................................................... 2
2. Operation .......................................................................................................... 3
3. Guarantee & S ervicing ..................................................................................... 4
All Time Electronics' instruments are subject to continuous development and improvement and in
consequence may incorporate minor detail changes from the information contained herein.
1. Specification
If voltages above 70V DC or 30V AC (RMS) are present the optional terminal shroud
kit (Part No. 9722) must be fitted.
Capacitance Range:
100ρF to 10µF in 100ρF steps
Accuracy:
± 1%, ±5 ρF, measured at 1 kHz
Residual Capacitance:
38ρF ±5 ρF (2 terminal measurement)
Maximum Operation Voltage:
63V A.C. (50 Hz, RMS). 100V D.C.
Power Factor:
Better than 0.007 (at 1 kHz)
Operating Temperature Range:
-10°C to + 50°C
Stability:
1% per year maximum
Dimensions:
215 x 100 x 120mm (incl. protective boot)
200 x 75 x 110mm (without)
Weight:
1kg (incl. protective boot), 0.64kg (without)
Optional Extras:
A carrying case is available for field and
industrial applications. (Code 9026)