SDS

Lamplight Farms, Inc.
4900 N. Lilly Road
Menomonee Falls, WI 53051
1-800-645-5267
(262) 781-9590
Filename: MSDS Ultra Pure Rev 3.doc Revision Date: 1/9/07
Revision 3
- 3 -
LAMPLIGHT
ULTRA-PURE
®
LAMP
OIL
7. HANDLING AND STORAGE
ELECTROSTATIC ACCUMULATION HAZARD:
Yes – ground all equipment.
USUAL SHIPPING CONTAINERS:
Tank cars, tank trucks.
STORAGE / TRANSPORT TEMPERATURE:
Ambient. (Product will freeze at 32° F (0° C))
STORAGE / TRANSPORT PRESSURE:
Ambient. (Product will freeze at 32° F (0° C))
LOAD / UNLOAD TEMPERATURE:
Ambient, above freezing point. (Product will freeze at 32° F (0° C))
STORAGE AND HANDLING MATERIALS:
Carbon steel is suitable.
8. EXPOSURE CONTROLS / PERSONAL PROTECTION
Engineering Controls
Air contaminant levels should be controlled below the PEL or TLV for this product (see Exposure
Guidelines of this section). Mechanical ventilation may be necessary if working with this product in
enclosed areas and at elevated temperatures.
Personal Protective Equipment
EYES:
When contact with liquid is possible, use a face shield and chemical goggles. Otherwise use safety
glasses or goggles.
SKIN:
Chemical gloves should be worn to prevent repeated contact. If potential for significant exposure to
liquid exists, use full protective clothing and chemical boots.
RESPIRATORY PROTECTION:
NIOSH-approved organic vapor air-purifying respirator, self contained breathing apparatus, or air-
supplied respirators dependent on concentration.