Installation Manual

TROUBLESHOOTING
30
TS4-F/TS4-A-F/TS4-A-2F:
Output voltage without active transmitter signal is 0.6V
Output voltage with active transmitter signal will be normal
module V
MP
or V
OC
If output is 0V contact Tigo support
Check that the system conforms to the design rules for TS4-F:
Up to 10 strings per RSS Core (CT)
Up to 30 modules per string
String length up to 1000ft (total cable length from + to - )
For longer distances please contact Tigo
Homeruns through RSS Core must be the same polarity
(all positive or all negative)
Match RSS Core polarity markings to ensure PLC signal ow in
the correct direction
RSS Transmitter:
Power LED should be lit and Signal LED should be blinking during
operation
Verify that RSS Core wiring and polarity are correct
Power cycle RSS Transmitter if Signal LED is unlit
While RSS Transmitter is powered off, string voltage should be
TS4-F/TS4-A-F: 0.6V * number of modules
TS4-A-2F: 0.6V * number of TS4s
While RSS Transmitter is powered on, full string voltage should be
present
Test individual strings with active RSS Transmitter
one at a time in case of unexpected voltage.