TS4-A-2F Installation Manual

TECHNICAL SPECIFICATIONS TS4-F
23
Electrical Ratings TS4-F Fire Safety
Input
Rated DC Input Power 475W
Input Voltage 16 - 90V
Max Continuous Input Current (I
MAX
) 12.5A
Output
Output Power Range 0 - 475W
Output Voltage Range 0 V
OC
Communication Type Power Line Communication (PLC)
Rapid Shutdown UL Listed (NEC 2017 & 2020 690.12) Yes
Impedance Matching Capability No
Output Voltage Limit No
Maximum System Voltage 1500V
Specify system voltage when ordering (1000V / 1500V) for appropriate cables & connectors.
Rapid shutdown activation requires RSS Transmitter.
Mechanical
Operating Temperature Range: -40°C to +70°C (-40°F to +158°F), RH < 85%
Storage Temperature Range: -40°C to +70°C (-40°F to +158°F), RH < 60%
Cooling Method Natural Convection
Dimensions (with cover) 178.5mm x 134mm x 25.5mm
Weight (base and cover) 670g
Outdoor Rating IP68, NEMA 3R
Cabling
Type H1Z2Z2-K
Output Length 1.2m standard, other lengths available
Cable Options 1000V rated, 1500V rated
Cable Cross-Section 6.3 ± 0.3mm
Connectors MC4, MC4 comparable
UV Resistance 500hr with UV light between 300-400nm @65C