TS4-A-2F Installation Manual

If cable trays must be used, only lay
conductors from the same transmitter
in the cable tray and twist pairs.
Run +/- string conductors from the
same string together through array and
conduit.
Run +/- string conductors from the
same transmitter together in the same
conduit.
12
When installing a system with 2 or more transmitters it is mandatory to use
the following best installation practices of PLC circuits to ensure a trouble-
free installation.
PV CONDUCTOR INSTALLATION
- MULTI-TRANSMITTER SYSTEMS -
REQUIRED PRACTICES
>8” (20cm)
X
X
X
The closer the conduit or cable tray the
greater potential for crosstalk to occur.
Never separate the + and of the same
string.
Twist the +/- of the string. Never separate the + and of the same
string.
Open cable trays provide no additional
protection from crosstalk. Never place
conductors from different transmitters
in the same Cable tray.