User's Manual
T90-DTU User Manual
14
“Node 1” NETID is 08.
“Node 2” NETID is 33.
Primary repeater 1‘s ’ADDH\ADDL are 08,33.
So the signal sent by node 1 (08) can be forwarded to node 2 (33)
At the same time, node 1 and node 2 have the same address, so the data transmitted by node 1 can be received by node 2.
② Secondary repeater
Secondary repeater’s ADDH\ADDL are 33,05.
Therefore, Repeater 2 can forward the data of Repeater 1 to the network NETID: 05.
Thus node 3 and node 4 can receive node 1 data. Node 4 outputs data normally, and node 3 has a different address than node 1, so no
data is output.
③ Two-way repeater
As shown in the figure: the data sent by node 1, the nodes 2, 4 can receive the data sent by node 2, 4, and node 1 can also receive it.
9. Application field
The data transceiver of TIE SMART SOLUTIONS CO,. LTD. is applied for all kinds of point to point, one
point to multiple points wireless data transmission system, such as smart home, Internet of things transformation,
power load monitoring, distribution network automation, hydrological and hydrological forecasting, water pipe
network monitoring, urban street lamps Monitoring, air defense alarm control, railway signal monitoring,
centralized control of railway water supply, oil supply pipe network monitoring, GPS system, remote meter reading,
electronic crane, automatic reporting, seismic forecasting, fire prevention, environmental monitoring and other
industrial automation system, as shown below: