Pad Bearing Capacity
ABS Pad Part# 1000 lbs. 2000 lbs. 3000 lbs.
Size Soil Soil Soil
16" x 18"- 2 Sq. Ft. 59300 2,000 lbs. 4,000 lbs. 6,000 lbs.
288 Sq. In.
16" x 22.5" - 2.5 Sq. Ft. 59301 2,500 lbs. 5,000 lbs. 7,500 lbs.
360 Sq. In.
17" x 25"- 3 Sq. Ft. 59302 3,000 lbs. 6,000 lbs. N/A
432 Sq. In.
24" x 24" - 4 Sq. Ft. 59303 4,000 lbs. 8,000 lbs. N/A
576 Sq. In.
Multi Pad Layout
32” X 22.5” (See 1 below) 3 X 59301 5,000 Lbs. 10,000 Lbs.*
5 Sq. Ft. - 720 Sq. In.
34.4 X 25.2 (See 2 below) 3 X 59302 6,000 Lbs. 12,000 Lbs.*
6 Sq. Ft. - 864 Sq. In.
* Concrete Block rated @ 8000 lbs. Double block any higher loads.
1. The 32 X 22.5 Pyramid configuration uses 2 - 16 X 22.5 pads placed side by side with
1 – 16 X 22.5 pad on top in the opposite direction.
2. The 34.4 X 25.4 Pyramid configuration uses 2 – 17.2 X 25.2 placed side by side with
1 – 17.2 X 25.2 Pad on top in the opposite direction.