Users Manual Part 2

Thundercomm TurboX C865 System on Module
Copyright © 2018 All Rights Reserved, Thundercomm Technology Co., Ltd.
3
4 Electrical Characteristics
4.1 Absolute Maximum Ratings
The SOM needs to be designed in the operation conditions which is shown as below table.
Parameter Min Max Units
Input Power Voltage
USB_VBUS -0.3 28 V
VB AT
-0.3
6
V
VBATT_CONN_VSENSE_P,
VBATT_CONN_VSENSE_M,
RSENSE_EXT_M,
RSENSE_EXT_P
-0.3 6 V
ESD
ESD-HBM model rating
±2000
V
ESD-CDM model rating
±500
V
Table 4.1-1 Absolute rating condition
Notes: for the ESD, it will be valid and available only when the module is fully tested and approved in the Initial
Production stage.
4.2 Operating Conditions
The SOM needs to be designed in the operation conditons which is shown as below table.
Parameters Min Typical Max Units
Input Power voltage
USB_VBUS
+3.6
5
+13.2
V
VB AT
+3.6
3.8
+4.8
V
VB AT
3
A
VBATT_CONN_VSENSE_P,
VBATT_CONN_VSENSE_M,
RSENSE_EXT_M,
RSENSE_EXT_P
+3.6 3.8 +4.8 V
Thermal conditions
Operating temperature -20 25 70 °C
Storage temperature
-40
-
70
°C