Data Sheet

THUNDERCOMM TurboX C40x SoM Datasheet
36
4 Electrical Characteristics
4.1 Absolute Maximum Ratings
The SoM needs to be desinged in the operatin conditons which is shown as below table beyond its
absolute maximum ratings may damage the device.
Parameter
Min
Max
Units
Input Power voltage
Voltage on any input or output pin
-0.5
VPH_PWR+0.5
V
VPH_PWR
-0.5
6.0
V
Table 4-1 Absolute rating condition
4.2 Operating Conditions
The SoM needs to be desinged in the operatin conditons which is shown as below table.
Parameters
Min
Typical
Max
Units
Input Power voltage
VPH_PWR
+3.0
3.6
+5.0
V
Supply voltage, digital I/O
+1.75
-
+1.85
V
VPH_PWR
0.8
A
Thermal conditions
Operating temperature
-20
25
70
°C
Storage temperature
-20
-
70
°C
Table 4-2 Operating condition
Note: For the thermal conditons, operatin and storage min and max temperature is only when the module
is fully tested and approved in the Initial Production stage.
4.3 Output Power
The SoM provide power supply for external device. Below map show the details.
Function
Default
voltage(V)
Programble
range(V)
Rated
current(mA)
Default
ON
Expected use