User Manual

Definitions
1.
2.
3.
4.
5.
6.
7.
1C charge : Current of 1 times the rated capacity of the battery. Example: 4000mAh Pack = 4A charge
2s: 2 CELLS in series connection. Example: a 2s pack has the voltage of 2 cells (3.7 X 2 = 7.4V).
CC Charge: Constant current charge.
CV charge: Constant voltage charge.
CH: Higher cell voltage.
CL: Lower cell voltage
Imbalance voltage: Maximum voltage differential between any cells within a pack.
Error Message and symptoms
1.
“Voltage error or Wrong Polarity”
Check Output battery connection.
Check Battery polarity
Battery may be over discharged (check battery voltage)
“TIMEOUT INITIAL CHARGE”
Battery is over discharged or wrong cell count. Run
a recovery sequence (See Rec overy charge). Check
cell counts.
“Wrong CELL COUNT”
Check the series cell count of the battery.
“Over Charge to 4.3V
Charge interrupted by an over charged cell.
Check individual cell voltages and run a balance charge using 0.5A current
setting. Monitor each cells voltage during this charge.
“UNDER VOLTGE”
Voltage too low, the battery was o ver discharged (any cell under approx. 3.6 volts) .
“CHARGING INCOMPLETED”
Charge not completed, check battery then charge again.
“Failure Input power”
Low INPUT Power voltage
Check INPUT POWER source capacity (10A, 12V minimum at maximum charge rating)
“Failure OUTPUT circuit”
Check battery connections.
“IMBALANCE OVER 0.2V”
Check battery pack voltage. The pack may have one or more unbalanced cells.
Charge at 0.5 amp while simultaneously balancing.
“SYSTEM TIME OUT”
Increase timeout setting (See “option settings”)
2.
3.
4.
5.
6.
7.
8.
9.
10.
How to check the data previous to an e rror interruption:
All the data previous to an error interruption (current/voltage/capacity/timer) is kept until the [Ent] button is pressed. Press simply press
the [Sel] button to retrieve. Note: A power interruption to the charger will cause a loss of this data.
to check it out what the progress was before interrupt.
**Press the [Sel] button
to retrieve.
the last interruped data
EC: charge
ED: discharge
TP610C
8
THUNDER POWER RC
ED: 21.000V 1.0A
01500mAh 0:00:00